Used YIZUMI for IMC Door Panels: Agree Appearance Acceptance
Select a used YIZUMI for an IMC door panel with defined visible regions, appearance references and measurement conditions, while keeping touch-function proof separate.
When selecting a used YIZUMI for an IMC door-panel project, agree what an acceptable decorated face looks like before judging the moulding demonstration. Identify the visible regions, reference parts, viewing conditions and any agreed measurements. Keep that appearance decision separate from whether the offered press has the required configuration and whether the completed panel’s touch functions work.
For buyers searching GEEPOW’s 500–3,300 metric-tonne procurement range, the actual nameplate clamp rating and original unit still need verification. The range is a sourcing filter, not evidence that a particular machine can produce your panel. Request the exact press, controller, tooling and documented process arrangement.
The illustration is an original purchasing diagram. Its zones and point labels are illustrative, not OEM geometry, a photograph, an inspection result or manufacturer-defined acceptance zones.
A real IMC application, with a limited conclusion
YIZUMI’s 29 November 2023 IPF Japan report describes a D1-E hybrid machine producing an IMC auto side-door panel with partner Hesheng Chuangjie. Here IMC means In-Mold Circuit: decorative patterns and conductive lines on film layers are integrated into a three-dimensional touch panel through injection moulding. The report identifies a particular demonstration and says its displayed data came from factory testing and are reference-only.
The exhibition equipment page identifies UN500D1-E with two-platen hydraulic clamping, electric-driven injection, a dedicated IMC tool and robots for insert placement and part removal. Before shortlisting, request the offered serial number’s controller/version, enabled interface and documented sequence, with an integrated trial showing film/insert positioning, transfer coordination and extraction using the intended tooling. A bench sample without that trial is appearance background; process capability remains unverified. Check physical mould compatibility separately.
Define the appearance agreement for this panel
VDA QMC’s public preface for VDA Volume 16, third edition 2016, describes it as a communication document rather than a new surface specification. It emphasises reproducible, preferably quantifiable definitions of relevant decorative features. That supports agreeing the customer’s actual requirement; it supplies no universal pass limit for this article.
Use this original worksheet with the panel designer and appearance approver.
| Region to identify on your drawing | Agreement to record | Evidence to retain |
|---|---|---|
| A — Main decorated face | Visible area, artwork revision and characteristics being judged. | Approved reference identity and location-marked observations. |
| B — Visible edges and curved transitions | Which areas remain visible in the intended installation and how they are assessed. | Part orientation and a drawing-linked observation map. |
| C — Symbols or control markings | Required visual position and registration against the product drawing. | Identified samples and the agreed comparison result. |
| Appearance beside neighbouring trim | Reference component and intended assembly/viewing position. | A recorded paired comparison, with unresolved differences visible. |
Name the person authorised to approve references and deviations. Retain each revision. A sample marked “good” needs defined viewing conditions and assessed areas.
Make a gloss reading interpretable on a 3D part
BYK-Gardner’s Gloss Measurement white paper explains that illumination and viewing conditions affect visual gloss, while measurement geometry influences instrument results. It also explains that conventional glossmeters are principally intended for flat surfaces: curvature and tilt can change a reading. This matters when a panel contains curved regions rather than a convenient flat test area.
Ask the measurement specialist to document the instrument, measurement geometry, aperture and exact locations used. Agree how the part is positioned or supported and whether the method is suitable at those locations. Retain the method beside the result. The guide provides no instrument choice, angle, gloss-unit tolerance or correction factor for your IMC panel.
When the proposed method cannot assess a location, record that limitation and agree another assessment. A result from a convenient flat area does not cover an unmeasured curved edge.
Compare the right attributes and retain the samples
BYK’s Overall Harmony of Consumer Electronics treats colour and gloss separately and highlights repeatable placement for small measurement areas. This is context for selecting appearance checks, not an IMC qualification method; one gloss result does not settle other attributes.
Use this original evidence sequence for the proposed used-machine trial:
- Identify the input: tool revision, decorative-film/artwork identity, resin, actual press configuration and run reference.
- Identify the part: label retained samples so each can be linked to its run and inspection map.
- Record the judgement: retain the reference identity, assessed regions, conditions, measurements and the named approver’s result.
- Record the open questions: list unassessed regions, deviations and any separate functional or product qualification still required.
The illustration’s labels are prompts for that record. They assign no severity class or permitted defect size. A customer-approved zone map and acceptance criteria must be developed for the real part.
Keep appearance and function as separate purchasing questions
An appearance record addresses the decorated surface under the agreed assessment. It does not establish touch response, circuit continuity, durability or other product requirements. Have the product owner define the necessary functional and product-qualification evidence without inferring it from a visually acceptable panel.
Likewise, a working touch demonstration does not close an unresolved surface question. Connect the press configuration, trial samples and appearance record through the same run identity, while giving each acceptance item its own outcome. Use the machine-specific acceptance guide to record what the run establishes and what remains conditional.
Compare offers against the same defined scope: identified machine and tooling arrangement, agreed samples and inspection record, included work and responsibility for unresolved items. Obtain quotations for any additional review or qualification.
Buyer questions
Does the D1-E exhibition prove that an offered D1 is IMC-ready?
No. Identify the actual machine and required process arrangement. The documented demonstration does not establish the used unit’s configuration or suitability.
Does one acceptable gloss value approve the decorated surface?
It addresses the measured characteristic, location and method. Other agreed appearance characteristics and unmeasured regions remain separate questions.
Can photographs replace the retained trial samples?
Photographs locate observations. Retain the physical samples, agreed comparison and measurement records required by the appearance approver.
Explore the 500–3,300 metric-tonne used-machine sourcing range, then send your panel drawing, appearance brief and machine identification. Include the proposed process arrangement, existing references and destination so the enquiry starts with the evidence your project needs.
Sources
- YIZUMI — Two Intelligent Solutions at IPF Japan 2023 (29 November 2023), IMC panel and factory-test limitation
- YIZUMI — IMC Panel for Auto Side Door Molding Solution, IPF Japan2023 equipment page (UN500D1-E configuration)
- VDA QMC — Volume 16, third edition 2016: public preface and purpose (full volume not reviewed)
- BYK-Gardner — Gloss Measurement, file version 20221114, sections on geometry and curved-surface limitations
- BYK-Gardner — Overall Harmony of Consumer Electronics, undated two-page technical article (printed pages18–19)